Siemens Simatic Hmi Comfort Outdoor Panels Firmware vulnerabilities
8 known vulnerabilities affecting siemens/simatic_hmi_comfort_outdoor_panels_firmware.
Total CVEs
8
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL1HIGH6MEDIUM1
Vulnerabilities
Page 1 of 1
CVE-2019-6572CRITICALCVSS 9.1fixed in 15.12019-05-14
CVE-2019-6572 [CRITICAL] CWE-200 CVE-2019-6572: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Upd
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Updat
nvd
CVE-2019-6576HIGHCVSS 7.5fixed in 15.12019-05-14
CVE-2019-6576 [HIGH] CWE-310 CVE-2019-6576: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Upd
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1)
nvd
CVE-2019-6577MEDIUMCVSS 5.4fixed in 15.12019-05-14
CVE-2019-6577 [MEDIUM] CWE-80 CVE-2019-6577: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Upd
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1
nvd
CVE-2019-6575HIGHCVSS 7.5fixed in 15.1v15.12019-04-17
CVE-2019-6575 [HIGH] CWE-248 CVE-2019-6575: A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions = V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanc
nvd
CVE-2019-6568HIGHCVSS 7.5fixed in 15.1v15.12019-04-17
CVE-2019-6568 [HIGH] CWE-125 CVE-2019-6568: The webserver of the affected devices contains a vulnerability that may lead to
a denial of service
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploita
nvd
CVE-2018-13814HIGHCVSS 8.8fixed in 14.02018-12-13
CVE-2018-13814 [HIGH] CWE-113 CVE-2018-13814: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIM
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All
nvd
CVE-2018-13813HIGHCVSS 8.1≤ 15.02018-12-13
CVE-2018-13813 [HIGH] CWE-601 CVE-2018-13813: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Updat
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMA
nvd
CVE-2018-13812HIGHCVSS 7.5≤ 15.02018-12-13
CVE-2018-13812 [HIGH] CWE-22 CVE-2018-13812: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Updat
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMAT
nvd