Siemens Simatic Hmi Comfort Panels vulnerabilities

9 known vulnerabilities affecting siemens/simatic_hmi_comfort_panels.

Total CVEs
9
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL2HIGH6MEDIUM1

Vulnerabilities

Page 1 of 1
CVE-2023-30756HIGHCVSS 8.2vAll versions2024-09-10
CVE-2023-30756 [HIGH] CWE-476 CVE-2023-30756: A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All vers
cvelistv5nvd
CVE-2023-28827HIGHCVSS 8.2vAll versions2024-09-10
CVE-2023-28827 [HIGH] CWE-476 CVE-2023-28827: A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All vers
cvelistv5nvd
CVE-2023-30755MEDIUMCVSS 5.9vAll versions2024-09-10
CVE-2023-30755 [MEDIUM] CWE-476 CVE-2023-30755: A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All ve
cvelistv5nvd
CVE-2022-40227HIGHCVSS 7.5vAll versions < V17 Update 42022-10-11
CVE-2022-40227 [HIGH] CWE-20 CVE-2022-40227: A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versi A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V17 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V17 Update 4), SIMATIC HMI KTP1200 Basic (All versions < V17 Update 5), SIMATIC HMI KTP400 Basic (All versions < V17 Update 5), SIMATIC HMI KTP700 Basic (All versions < V17 Update 5), SIM
cvelistv5nvd
CVE-2020-15798CRITICALCVSS 9.8vAll versions < V16 Update 3a2021-02-09
CVE-2020-15798 [CRITICAL] CWE-306 CVE-2020-15798: A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versi A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAM
cvelistv5nvd
CVE-2020-15786CRITICALCVSS 9.8vAll versions <= V162020-09-09
CVE-2020-15786 [CRITICAL] CWE-307 CVE-2020-15786: A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variant A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block exces
cvelistv5nvd
CVE-2019-10936HIGHCVSS 7.5fixed in *2019-10-10
CVE-2019-10936 [HIGH] CWE-400 CVE-2019-10936: Affected devices improperly handle large amounts of specially crafted UDP packets. This could all Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
cvelistv5nvd
CVE-2017-2681HIGHCVSS 7.1fixed in 15.12017-05-11
CVE-2017-2681 [HIGH] CWE-400 CVE-2017-2681: Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected pro Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
nvd
CVE-2017-2680HIGHCVSS 7.1fixed in 15.12017-05-11
CVE-2017-2680 [HIGH] CWE-400 CVE-2017-2680: Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affect Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.