Siemens Simatic Hmi Comfort Panels Firmware vulnerabilities

10 known vulnerabilities affecting siemens/simatic_hmi_comfort_panels_firmware.

Total CVEs
10
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL2HIGH6MEDIUM2

Vulnerabilities

Page 1 of 1
CVE-2022-40227HIGHCVSS 7.5fixed in 17.0v17.02022-10-11
CVE-2022-40227 [HIGH] CWE-20 CVE-2022-40227: A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versi A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V17 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V17 Update 4), SIMATIC HMI KTP1200 Basic (All versions < V17 Update 5), SIMATIC HMI KTP400 Basic (All versions < V17 Update 5), SIMATIC HMI KTP700 Basic (All versions < V17 Update 5), SIM
nvd
CVE-2019-19276MEDIUMCVSS 5.3v162021-05-12
CVE-2019-19276 [MEDIUM] CWE-787 CVE-2019-19276: A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS varia A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resu
nvd
CVE-2020-15798CRITICALCVSS 9.8fixed in 16.0v16.02021-02-09
CVE-2020-15798 [CRITICAL] CWE-306 CVE-2020-15798: A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versi A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAM
nvd
CVE-2019-6572CRITICALCVSS 9.1fixed in 15.12019-05-14
CVE-2019-6572 [CRITICAL] CWE-200 CVE-2019-6572: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Upd A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Updat
nvd
CVE-2019-6576HIGHCVSS 7.5fixed in 15.12019-05-14
CVE-2019-6576 [HIGH] CWE-310 CVE-2019-6576: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Upd A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1)
nvd
CVE-2019-6577MEDIUMCVSS 5.4fixed in 15.12019-05-14
CVE-2019-6577 [MEDIUM] CWE-80 CVE-2019-6577: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Upd A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1
nvd
CVE-2019-6568HIGHCVSS 7.5fixed in 15.1v15.12019-04-17
CVE-2019-6568 [HIGH] CWE-125 CVE-2019-6568: The webserver of the affected devices contains a vulnerability that may lead to a denial of service The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploita
nvd
CVE-2018-13814HIGHCVSS 8.8fixed in 14.02018-12-13
CVE-2018-13814 [HIGH] CWE-113 CVE-2018-13814: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIM A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All
nvd
CVE-2018-13813HIGHCVSS 8.1≤ 15.02018-12-13
CVE-2018-13813 [HIGH] CWE-601 CVE-2018-13813: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Updat A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMA
nvd
CVE-2018-13812HIGHCVSS 7.5≤ 15.02018-12-13
CVE-2018-13812 [HIGH] CWE-22 CVE-2018-13812: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Updat A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMAT
nvd