Siemens Simatic S7-1500 Cpu Firmware vulnerabilities

14 known vulnerabilities affecting siemens/simatic_s7-1500_cpu_firmware.

Total CVEs
14
CISA KEV
0
Public exploits
1
Exploited in wild
0
Severity breakdown
HIGH8MEDIUM6

Vulnerabilities

Page 1 of 1
CVE-2022-25622HIGHCVSS 7.5fixed in 2.0.02022-04-12
CVE-2022-25622 [MEDIUM] CWE-400 CVE-2022-25622: The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
nvd
CVE-2019-10936HIGHCVSS 7.5fixed in 2.02019-10-10
CVE-2019-10936 [HIGH] CWE-400 CVE-2019-10936: Affected devices improperly handle large amounts of specially crafted UDP packets. This could all Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
nvd
CVE-2016-2200HIGHCVSS 7.5≤ 1.8.22016-02-08
CVE-2016-2200 [HIGH] CWE-20 CVE-2016-2200: Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service (STOP mode transition) via crafted packets on TCP port 102.
nvd
CVE-2016-2201MEDIUMCVSS 5.3v1.8.22016-02-08
CVE-2016-2201 [MEDIUM] CWE-20 CVE-2016-2201: Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protectio Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102.
nvd
CVE-2014-5074HIGHCVSS 7.1PoC≤ 1.5.1v1.0.1+4 more2014-08-17
CVE-2014-5074 [HIGH] CVE-2014-5074: Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denia Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets.
nvd
CVE-2014-2257HIGHCVSS 7.8≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2257 [HIGH] CVE-2014-2257: Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets.
nvd
CVE-2014-2259HIGHCVSS 7.8≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2259 [HIGH] CVE-2014-2259: Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets.
nvd
CVE-2014-2251HIGHCVSS 8.3≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2251 [HIGH] CVE-2014-2251: The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 do The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors.
nvd
CVE-2014-2255HIGHCVSS 7.8≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2255 [HIGH] CVE-2014-2255: Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets.
nvd
CVE-2014-2253MEDIUMCVSS 6.1≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2253 [MEDIUM] CVE-2014-2253: Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets.
nvd
CVE-2014-2247MEDIUMCVSS 5.8≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2247 [MEDIUM] CVE-2014-2247: The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allo The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors.
nvd
CVE-2014-2249MEDIUMCVSS 5.8≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2249 [MEDIUM] CWE-352 CVE-2014-2249: Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firm Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
nvd
CVE-2014-2246MEDIUMCVSS 4.3≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2246 [MEDIUM] CWE-79 CVE-2014-2246: Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
nvd
CVE-2014-2248MEDIUMCVSS 4.3≤ 1.1.2v1.0.1+2 more2014-03-16
CVE-2014-2248 [MEDIUM] CVE-2014-2248: Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.
nvd