Siemens Simatic Wincc Runtime Professional V17 vulnerabilities
4 known vulnerabilities affecting siemens/simatic_wincc_runtime_professional_v17.
Total CVEs
4
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
HIGH3MEDIUM1
Vulnerabilities
Page 1 of 1
CVE-2023-46280HIGHCVSS 8.2fixed in V17 Update 82024-05-14
CVE-2023-46280 [HIGH] CWE-125 CVE-2023-46280: A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Aut
A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMAT
cvelistv5nvd
CVE-2023-50821MEDIUMCVSS 6.9fixed in V17 Update 82024-04-09
CVE-2023-50821 [MEDIUM] CWE-120 CVE-2023-50821: A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC Wi
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update
cvelistv5nvd
CVE-2023-28831HIGHCVSS 8.7fixed in *2023-09-12
CVE-2023-28831 [HIGH] CWE-190 CVE-2023-28831: The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnera
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.
This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
cvelistv5nvd
CVE-2022-24287HIGHCVSS 7.8vAll versions < V17 Upd42022-05-20
CVE-2022-24287 [HIGH] CWE-1188 CVE-2022-24287: A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All ve
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC
cvelistv5nvd