CVE-2025-30033HIGHCVSS 8.5fixed in V20 Update 42025-08-12
CVE-2025-30033 [HIGH] CWE-427 CVE-2025-30033: The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
cvelistv5nvd
CVE-2025-27127MEDIUMCVSS 5.3fixed in V20 Update 32025-07-08
CVE-2025-27127 [MEDIUM] CWE-434 CVE-2025-27127: A vulnerability has been identified in TIA Project-Server (All versions < V2.1.1), TIA Project-Serve
A vulnerability has been identified in TIA Project-Server (All versions < V2.1.1), TIA Project-Server V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 4), Tota
cvelistv5nvd
CVE-2025-30175HIGHCVSS 8.7fixed in *2025-05-13
CVE-2025-30175 [HIGH] CWE-787 CVE-2025-30175: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation
cvelistv5nvd
CVE-2025-30176HIGHCVSS 8.7fixed in *2025-05-13
CVE-2025-30176 [HIGH] CWE-125 CVE-2025-30176: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation
cvelistv5nvd
CVE-2025-30174HIGHCVSS 8.7fixed in *2025-05-13
CVE-2025-30174 [HIGH] CWE-125 CVE-2025-30174: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation
cvelistv5nvd
CVE-2023-30757MEDIUMCVSS 5.5fixed in *2023-06-13
CVE-2023-30757 [MEDIUM] CWE-693 CVE-2023-30757: A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All ve
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation
cvelistv5nvd