Siemens User Management Component vulnerabilities
8 known vulnerabilities affecting siemens/user_management_component.
Total CVEs
8
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL1HIGH7
Vulnerabilities
Page 1 of 1
CVE-2026-25656HIGHCVSS 8.5fixed in 2.15.2.12026-02-10
CVE-2026-25656 [HIGH] CWE-427 CVE-2026-25656: A vulnerability has been identified in SINEC NMS (All versions), User Management Component (UMC) (Al
A vulnerability has been identified in SINEC NMS (All versions), User Management Component (UMC) (All versions < V2.15.2.1). The affected application permits improper modification of a configuration file by a low-privileged user.
This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with SYSTEM privileges
nvd
CVE-2025-40795CRITICALCVSS 9.3fixed in 2.15.1.32025-09-09
CVE-2025-40795 [CRITICAL] CWE-121 CVE-2025-40795: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated
nvd
CVE-2025-40796HIGHCVSS 8.7fixed in 2.15.1.32025-09-09
CVE-2025-40796 [HIGH] CWE-125 CVE-2025-40796: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attack
nvd
CVE-2025-40797HIGHCVSS 8.7fixed in 2.15.1.32025-09-09
CVE-2025-40797 [HIGH] CWE-125 CVE-2025-40797: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attack
nvd
CVE-2025-40798HIGHCVSS 8.7fixed in 2.15.1.32025-09-09
CVE-2025-40798 [HIGH] CWE-125 CVE-2025-40798: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attack
nvd
CVE-2025-30175HIGHCVSS 8.7fixed in 2.15.1.12025-05-13
CVE-2025-30175 [HIGH] CWE-787 CVE-2025-30175: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation
nvd
CVE-2025-30176HIGHCVSS 8.7fixed in 2.15.1.12025-05-13
CVE-2025-30176 [HIGH] CWE-125 CVE-2025-30176: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation
nvd
CVE-2025-30174HIGHCVSS 8.7fixed in 2.15.1.12025-05-13
CVE-2025-30174 [HIGH] CWE-125 CVE-2025-30174: A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (Al
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation
nvd