CVE-2023-30897HIGHCVSS 7.8fixed in 7.5.2.132023-06-13
CVE-2023-30897 [HIGH] CWE-732 CVE-2023-30897: A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applicatio
A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation.
This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
nvd
CVE-2017-12069HIGHCVSS 8.2≤ 7.42017-08-30
CVE-2017-12069 [HIGH] CWE-611 CVE-2017-12069: An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Sof
nvd
CVE-2015-2823MEDIUMCVSS 6.8v7.0v7.1+3 more2015-04-08
CVE-2015-2823 [MEDIUM] CWE-287 CVE-2015-2823: Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI C
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Porta
nvd
CVE-2015-2822MEDIUMCVSS 4.3≤ 13.02015-04-08
CVE-2015-2822 [MEDIUM] CWE-20 CVE-2015-2822: Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime A
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102.
nvd
CVE-2015-1358MEDIUMCVSS 5.0v13.02015-02-18
CVE-2015-1358 [MEDIUM] CWE-310 CVE-2015-1358: The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functi
The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to
nvd
CVE-2014-4683MEDIUMCVSS 4.9≤ 7.2v5.0+3 more2014-07-24
CVE-2014-4683 [MEDIUM] CWE-264 CVE-2014-4683: The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, all
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
nvd
CVE-2014-4682MEDIUMCVSS 5.0≤ 7.2v5.0+3 more2014-07-24
CVE-2014-4682 [MEDIUM] CWE-200 CVE-2014-4682: The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, all
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.
nvd
CVE-2014-4685MEDIUMCVSS 4.6≤ 7.2v5.0+3 more2014-07-24
CVE-2014-4685 [MEDIUM] CWE-264 CVE-2014-4685: Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain pri
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
nvd
CVE-2014-4684MEDIUMCVSS 6.0≤ 7.2v5.0+3 more2014-07-24
CVE-2014-4684 [MEDIUM] CWE-264 CVE-2014-4684: The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.
nvd
CVE-2014-4686MEDIUMCVSS 6.8≤ 7.2v5.0+3 more2014-07-24
CVE-2014-4686 [MEDIUM] CVE-2014-4686: The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and othe
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.
nvd
CVE-2013-4912MEDIUMCVSS 5.8v11.0v12.02013-08-01
CVE-2013-4912 [MEDIUM] CWE-20 CVE-2013-4912: Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote atta
Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.
nvd
CVE-2013-4911MEDIUMCVSS 6.8v11.0v12.02013-08-01
CVE-2013-4911 [MEDIUM] CWE-352 CVE-2013-4911: Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP
Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.
nvd
CVE-2013-3958HIGHCVSS 7.5≤ 7.2v7.0+1 more2013-06-14
CVE-2013-3958 [HIGH] CWE-255 CVE-2013-3958: The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMAT
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.
nvd
CVE-2013-3957HIGHCVSS 7.5≤ 7.2v7.0+1 more2013-06-14
CVE-2013-3957 [HIGH] CWE-89 CVE-2013-3957: SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Upd
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
nvd
CVE-2013-3959MEDIUMCVSS 4.0≤ 7.2v7.0+1 more2013-06-14
CVE-2013-3959 [MEDIUM] CWE-200 CVE-2013-3959: The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.
nvd
CVE-2013-0676MEDIUMCVSS 4.0≤ 7.1v5.0+2 more2013-03-21
CVE-2013-0676 [MEDIUM] CWE-264 CVE-2013-0676: Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not proper
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
nvd
CVE-2013-0677MEDIUMCVSS 5.8≤ 7.1v5.0+2 more2013-03-21
CVE-2013-0677 [MEDIUM] CWE-200 CVE-2013-0677: The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other product
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
nvd
CVE-2013-0674MEDIUMCVSS 6.8≤ 7.1v5.0+2 more2013-03-21
CVE-2013-0674 [MEDIUM] CWE-119 CVE-2013-0674: Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.
nvd
CVE-2013-0679MEDIUMCVSS 4.0≤ 7.1v5.0+2 more2013-03-21
CVE-2013-0679 [MEDIUM] CWE-22 CVE-2013-0679: Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
nvd
CVE-2013-0678MEDIUMCVSS 4.0≤ 7.0v7.02013-03-21
CVE-2013-0678 [MEDIUM] CWE-255 CVE-2013-0678: Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not proper
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.