cbcvebase.

Softing Opc vulnerabilities

17 known vulnerabilities affecting softing/opc.

Total CVEs
17
CISA KEV
0
Public exploits
2
Exploited in wild
0
Severity breakdown
CRITICAL2HIGH14MEDIUM1

Vulnerabilities

Page 1 of 1
CVE-2022-1373P2HIGHCVSS 7.2PoCv5.22022-08-17
CVE-2022-1373 [HIGH] CWE-23 CVE-2022-1373: The “restore configuration” feature of Softing Secure Integration Server V1.22 is vulnerable to a di The “restore configuration” feature of Softing Secure Integration Server V1.22 is vulnerable to a directory traversal vulnerability when processing zip files. An attacker can craft a zip file to load an arbitrary dll and execute code. Using the "restore configuration" feature to upload a zip file containing a path traversal file may cause a file to be cr
nvd
CVE-2022-2334P3HIGHCVSS 7.2PoCv5.22022-08-17
CVE-2022-2334 [HIGH] CWE-427 CVE-2022-2334: The application searches for a library dll that is not found. If an attacker can place a dll with th The application searches for a library dll that is not found. If an attacker can place a dll with this name, then the attacker can leverage it to execute arbitrary code on the targeted Softing Secure Integration Server V1.22.
nvd
CVE-2020-14524P3CRITICALCVSS 9.8fixed in 4.47.02020-08-25
CVE-2020-14524 [CRITICAL] CWE-122 CVE-2020-14524: Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
nvd
CVE-2022-2336P3CRITICALCVSS 9.8v5.22022-08-17
CVE-2022-2336 [CRITICAL] CWE-287 CVE-2022-2336: Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`. This allows Softing to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the `admin`
nvd
CVE-2023-37572P3HIGHCVSS 7.5fixed in 5.302023-12-05
CVE-2023-37572 [HIGH] CWE-276 CVE-2023-37572: Softing OPC Suite version 5.25 and before has Incorrect Access Control, allows attackers to obtain s Softing OPC Suite version 5.25 and before has Incorrect Access Control, allows attackers to obtain sensitive information via weak permissions in OSF_discovery service. The service executable could be changed or the service could be deleted.
nvd
CVE-2022-2335P3HIGHCVSS 7.5v5.22022-08-17
CVE-2022-2335 [HIGH] CWE-191 CVE-2022-2335: A crafted HTTP packet with a -1 content-length header can create a denial-of-service condition in So A crafted HTTP packet with a -1 content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
nvd
CVE-2022-2337P3HIGHCVSS 7.5v5.22022-08-17
CVE-2022-2337 [HIGH] CWE-476 CVE-2022-2337: A crafted HTTP packet with a missing HTTP URI can create a denial-of-service condition in Softing Se A crafted HTTP packet with a missing HTTP URI can create a denial-of-service condition in Softing Secure Integration Server V1.22.
nvd
CVE-2020-14522P3HIGHCVSS 7.5fixed in 4.47.02020-08-25
CVE-2020-14522 [HIGH] CWE-400 CVE-2020-14522: Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected product is vulnerable to uncontrolled resource consumption, which may allow an attacker to cause a denial-of-service condition.
nvd
CVE-2022-1069P3HIGHCVSS 7.5v5.22022-08-17
CVE-2022-1069 [HIGH] CWE-125 CVE-2022-1069: A crafted HTTP packet with a large content-length header can create a denial-of-service condition in A crafted HTTP packet with a large content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
nvd
CVE-2022-2547P3HIGHCVSS 7.5v5.22022-08-17
CVE-2022-2547 [HIGH] CWE-476 CVE-2022-2547: A crafted HTTP packet without a content-type header can create a denial-of-service condition in Soft A crafted HTTP packet without a content-type header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
nvd
CVE-2021-40873P3HIGHCVSS 7.5fixed in 5.662021-11-10
CVE-2021-40873 [HIGH] CWE-415 CVE-2021-40873: An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and uaToolkit E An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a client or server. The server process may crash unexpectedly because of a double free, and must be restarted.
nvd
CVE-2022-1748P3HIGHCVSS 7.5v5.22022-08-17
CVE-2022-1748 [HIGH] CWE-476 CVE-2022-1748: Softing OPC UA C++ Server SDK, Secure Integration Server, edgeConnector, edgeAggregator, OPC Suite, Softing OPC UA C++ Server SDK, Secure Integration Server, edgeConnector, edgeAggregator, OPC Suite, and uaGate are affected by a NULL pointer dereference vulnerability.
nvd
CVE-2022-37453P3HIGHCVSS 7.5≤ 5.222022-10-20
CVE-2022-37453 [HIGH] CWE-787 CVE-2022-37453: An issue was discovered in Softing OPC UA C++ SDK before 6.10. A buffer overflow or an excess alloca An issue was discovered in Softing OPC UA C++ SDK before 6.10. A buffer overflow or an excess allocation happens due to unchecked array and matrix bounds in structure data types.
nvd
CVE-2022-39823P3HIGHCVSS 7.5≥ 5.20, ≤ 5.222022-10-20
CVE-2022-39823 [HIGH] CWE-416 CVE-2022-39823: An issue was discovered in Softing OPC UA C++ SDK 5.66 through 6.x before 6.10. An OPC/UA browse req An issue was discovered in Softing OPC UA C++ SDK 5.66 through 6.x before 6.10. An OPC/UA browse request exceeding the server limit on continuation points may cause a use-after-free error
nvd
CVE-2021-40871P4HIGHCVSS 7.5fixed in 5.662021-11-10
CVE-2021-40871 [HIGH] CWE-843 CVE-2021-40871: An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66. Remote attacker An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a OPC/UA client. The client process may crash unexpectedly because of a wrong type cast, and must be restarted.
nvd
CVE-2023-41151P4HIGHCVSS 7.5≤ 5.302023-12-14
CVE-2023-41151 [HIGH] CWE-755 CVE-2023-41151: An uncaught exception issue discovered in Softing OPC UA C++ SDK before 6.30 for Windows operating s An uncaught exception issue discovered in Softing OPC UA C++ SDK before 6.30 for Windows operating system may cause the application to crash when the server wants to send an error packet, while socket is blocked on writing.
nvd
CVE-2022-2338P4MEDIUMCVSS 5.3v5.22022-08-17
CVE-2022-2338 [MEDIUM] CWE-319 CVE-2022-2338: Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the- Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the request, which may be captured for use in authenticating to the server.
nvd
Softing Opc vulnerabilities | cvebase