cbcvebase.

Tenda Ac10 Firmware vulnerabilities

92 known vulnerabilities affecting tenda/ac10_firmware.

Total CVEs
92
CISA KEV
1
actively exploited
Public exploits
0
Exploited in wild
1
Severity breakdown
CRITICAL45HIGH30MEDIUM16LOW1

Vulnerabilities

Page 2 of 5
CVE-2025-25457HIGHCVSS 7.5v16.03.10.202025-04-17
CVE-2025-25457 [HIGH] CWE-121 CVE-2025-25457: Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via cloneType2. Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via cloneType2.
nvd
CVE-2025-25456CRITICALCVSS 9.8v16.03.10.202025-04-15
CVE-2025-25456 [CRITICAL] CWE-120 CVE-2025-25456: Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2. Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2.
nvd
CVE-2025-25458MEDIUMCVSS 4.6v16.03.10.202025-04-15
CVE-2025-25458 [MEDIUM] CWE-120 CVE-2025-25458: Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serverName2. Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serverName2.
nvd
CVE-2025-25453MEDIUMCVSS 4.6v16.03.10.202025-04-15
CVE-2025-25453 [MEDIUM] CWE-120 CVE-2025-25453: Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serviceName2. Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serviceName2.
nvd
CVE-2025-3161HIGHCVSS 8.7v16.03.10.132025-04-03
CVE-2025-3161 [HIGH] CWE-119 CVE-2025-3161: A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects t A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
nvd
CVE-2025-25674CRITICALCVSS 9.8v15.03.06.232025-02-20
CVE-2025-25674 [CRITICAL] CWE-120 CVE-2025-25674: Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid.
nvd
CVE-2025-25675CRITICALCVSS 9.8v15.03.06.232025-02-20
CVE-2025-25675 [CRITICAL] CWE-77 CVE-2025-25675: Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand fu Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directly used in the doSystemCmd function, causing an arbitrary command execution.
nvd
CVE-2025-0528HIGHCVSS 8.6v16.03.10.202025-01-17
CVE-2025-0528 [HIGH] CWE-74 CVE-2025-0528: A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03. A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and
nvd
CVE-2024-11248HIGHCVSS 8.7v16.03.10.132024-11-15
CVE-2024-11248 [HIGH] CWE-119 CVE-2024-11248: A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this iss A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be
nvd
CVE-2024-11061HIGHCVSS 8.7v16.03.10.132024-11-11
CVE-2024-11061 [HIGH] CWE-119 CVE-2024-11061: A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnera A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be u
nvd
CVE-2024-11056HIGHCVSS 8.7v16.03.10.132024-11-10
CVE-2024-11056 [HIGH] CWE-119 CVE-2024-11056: A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
nvd
CVE-2024-10280HIGHCVSS 7.1v16.03.10.13v16.03.10.20+2 more2024-10-23
CVE-2024-10280 [HIGH] CWE-476 CVE-2024-10280: A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit
nvd
CVE-2024-33365HIGHCVSS 7.5v16.03.10.202024-07-29
CVE-2024-33365 [HIGH] CWE-120 CVE-2024-33365: Buffer Overflow vulnerability in Tenda AC10 v4 US_AC10V4.0si_V16.03.10.20_cn allows a remote attacke Buffer Overflow vulnerability in Tenda AC10 v4 US_AC10V4.0si_V16.03.10.20_cn allows a remote attacker to execute arbitrary code via the Virtual_Data_Check function in the bin/httpd component.
nvd
CVE-2024-32317HIGHCVSS 7.5v16.03.10.13v16.03.10.202024-04-17
CVE-2024-32317 [HIGH] CWE-121 CVE-2024-32317: Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the ad Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
nvd
CVE-2024-2856CRITICALCVSS 9.8v16.03.10.13v16.03.10.202024-03-24
CVE-2024-2856 [CRITICAL] CWE-121 CVE-2024-2856: A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10 A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the pu
nvd
CVE-2024-2581HIGHCVSS 8.8v16.03.10.132024-03-18
CVE-2024-2581 [HIGH] CWE-121 CVE-2024-2581: A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects t A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The ident
nvd
CVE-2024-25373MEDIUMCVSS 4.6v16.03.10.202024-02-15
CVE-2024-25373 [MEDIUM] CWE-120 CVE-2024-25373: Tenda AC10V4.0 V16.03.10.20 was discovered to contain a stack overflow via the page parameter in the Tenda AC10V4.0 V16.03.10.20 was discovered to contain a stack overflow via the page parameter in the sub_49B384 function.
nvd
CVE-2023-45484CRITICALCVSS 9.8v16.03.10.132023-11-29
CVE-2023-45484 [CRITICAL] CWE-787 CVE-2023-45484: Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic.
nvd
CVE-2023-45481CRITICALCVSS 9.8v16.03.10.132023-11-29
CVE-2023-45481 [CRITICAL] CWE-787 CVE-2023-45481: Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
nvd
CVE-2023-45483CRITICALCVSS 9.8v16.03.10.132023-11-29
CVE-2023-45483 [CRITICAL] CWE-787 CVE-2023-45483: Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time.
nvd