Tenda Ac10U Firmware vulnerabilities
18 known vulnerabilities affecting tenda/ac10u_firmware.
Total CVEs
18
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL2HIGH15MEDIUM1
Vulnerabilities
Page 1 of 1
CVE-2025-15218HIGHCVSS 7.4v15.03.06.48v15.03.06.492025-12-30
CVE-2025-15218 [HIGH] CWE-119 CVE-2025-15218: A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerabilit
A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing a manipulation of the argument lanMask can lead to buffer overflow. The attack can be launched remotely. The exploit has been ma
nvd
CVE-2025-15215HIGHCVSS 7.4v15.03.06.48v15.03.06.492025-12-30
CVE-2025-15215 [HIGH] CWE-119 CVE-2025-15215: A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function for
A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and m
nvd
CVE-2024-10280HIGHCVSS 7.1v15.03.06.48v15.03.06.492024-10-23
CVE-2024-10280 [HIGH] CWE-476 CVE-2024-10280: A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit
nvd
CVE-2024-32306MEDIUMCVSS 5.7v15.03.06.48v15.03.06.492024-04-17
CVE-2024-32306 [MEDIUM] CWE-121 CVE-2024-32306: Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parame
Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
nvd
CVE-2024-30612HIGHCVSS 8.1v15.03.06.482024-03-28
CVE-2024-30612 [HIGH] CWE-121 CVE-2024-30612: Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedU
Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function.
nvd
CVE-2024-2853CRITICALCVSS 9.8v15.03.06.48v15.03.06.492024-03-24
CVE-2024-2853 [MEDIUM] CWE-78 CVE-2024-2853: A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. Thi
A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The
nvd
CVE-2024-2763HIGHCVSS 8.8v15.03.06.482024-03-21
CVE-2024-2763 [HIGH] CWE-121 CVE-2024-2763: A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affect
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The
nvd
CVE-2024-2764HIGHCVSS 8.8v15.03.06.482024-03-21
CVE-2024-2764 [HIGH] CWE-121 CVE-2024-2764: A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affect
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be use
nvd
CVE-2024-2707HIGHCVSS 8.8v15.03.06.492024-03-20
CVE-2024-2707 [MEDIUM] CWE-78 CVE-2024-2707: A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerabi
A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458
nvd
CVE-2024-2708HIGHCVSS 8.8v15.03.06.492024-03-20
CVE-2024-2708 [HIGH] CWE-121 CVE-2024-2708: A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects
A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated
nvd
CVE-2024-2710HIGHCVSS 8.8v15.03.06.492024-03-20
CVE-2024-2710 [HIGH] CWE-121 CVE-2024-2710: A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and m
nvd
CVE-2024-2709HIGHCVSS 8.8v15.03.06.492024-03-20
CVE-2024-2709 [HIGH] CWE-121 CVE-2024-2709: A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected i
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used
nvd
CVE-2024-2706HIGHCVSS 8.8v15.03.06.492024-03-20
CVE-2024-2706 [HIGH] CWE-121 CVE-2024-2706: A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affect
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Th
nvd
CVE-2024-2711HIGHCVSS 8.8v15.03.06.482024-03-20
CVE-2024-2711 [HIGH] CWE-121 CVE-2024-2711: A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by thi
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be us
nvd
CVE-2024-2704HIGHCVSS 8.8v15.03.06.492024-03-20
CVE-2024-2704 [HIGH] CWE-121 CVE-2024-2704: A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulner
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be u
nvd
CVE-2024-2703HIGHCVSS 8.8v15.03.06.492024-03-20
CVE-2024-2703 [HIGH] CWE-121 CVE-2024-2703: A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the fu
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-25745
nvd
CVE-2024-2705HIGHCVSS 8.8v15.03.06.492024-03-20
CVE-2024-2705 [HIGH] CWE-121 CVE-2024-2705: A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Af
A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and ma
nvd
CVE-2024-0924CRITICALCVSS 9.8v15.03.06.49_multi_tde012024-01-26
CVE-2024-0924 [MEDIUM] CWE-121 CVE-2024-0924: A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01.
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB
nvd