cbcvebase.

Deltaww Infrasuite Device Master vulnerabilities

31 known vulnerabilities affecting deltaww/infrasuite_device_master.

Total CVEs
31
CISA KEV
0
Public exploits
1
Exploited in wild
0
Severity breakdown
CRITICAL13HIGH18

Vulnerabilities

Page 1 of 2
CVE-2023-1133P1CRITICALCVSS 9.8PoCfixed in 1.0.52023-03-27
CVE-2023-1133 [CRITICAL] CWE-502 CVE-2023-1133: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code.
nvd
CVE-2022-38142P2CRITICALCVSS 9.8fixed in 00.00.02a2022-10-31
CVE-2022-38142 [CRITICAL] CWE-502 CVE-2022-38142: Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied d Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
nvd
CVE-2022-41657P2CRITICALCVSS 9.8fixed in 00.00.02a2022-10-31
CVE-2022-41657 [CRITICAL] CWE-22 CVE-2022-41657: Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided dat Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
nvd
CVE-2022-41772P2CRITICALCVSS 9.8fixed in 00.00.02a2022-10-31
CVE-2022-41772 [CRITICAL] CWE-22 CVE-2022-41772: Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives con Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
nvd
CVE-2023-47207P2CRITICALCVSS 9.8v1.0.72023-11-30
CVE-2023-47207 [CRITICAL] CWE-502 CVE-2023-47207: In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthe In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute code with local administrator privileges.
nvd
CVE-2022-40202P2CRITICALCVSS 9.8fixed in 00.00.02a2022-10-31
CVE-2022-40202 [CRITICAL] CWE-306 CVE-2022-40202: The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and p The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all functio
nvd
CVE-2023-39226P2CRITICALCVSS 9.8v1.0.72023-11-30
CVE-2023-39226 [CRITICAL] CWE-749 CVE-2023-39226: In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthe In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet.
nvd
CVE-2023-1140P2CRITICALCVSS 9.8fixed in 1.0.52023-03-27
CVE-2023-1140 [CRITICAL] CWE-306 CVE-2023-1140: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that coul Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
nvd
CVE-2022-41779P2CRITICALCVSS 9.8fixed in 00.00.02a2022-10-31
CVE-2022-41779 [CRITICAL] CWE-502 CVE-2022-41779: Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
nvd
CVE-2023-1141P2HIGHCVSS 8.8fixed in 1.0.52023-03-27
CVE-2023-1141 [HIGH] CWE-77 CVE-2023-1141: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulne Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution.
nvd
CVE-2023-30765P2CRITICALCVSS 9.8fixed in 1.0.72023-07-10
CVE-2023-30765 [CRITICAL] CWE-269 CVE-2023-30765: ​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls ​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.
nvd
CVE-2023-1139P2HIGHCVSS 8.8fixed in 1.0.52023-03-27
CVE-2023-1139 [HIGH] CWE-502 CVE-2023-1139: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.
nvd
CVE-2023-1142P3CRITICALCVSS 9.8fixed in 1.0.52023-03-27
CVE-2023-1142 [CRITICAL] CWE-22 CVE-2023-1142: In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL dec In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.
nvd
CVE-2022-41629P3CRITICALCVSS 9.1fixed in 00.00.02a2022-10-31
CVE-2022-41629 [CRITICAL] CWE-306 CVE-2022-41629: Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing adm
nvd
CVE-2023-34347P3CRITICALCVSS 9.8fixed in 1.0.72023-07-10
CVE-2023-34347 [CRITICAL] CWE-502 CVE-2023-34347: ​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot ​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.
nvd
CVE-2022-41778P3HIGHCVSS 8.8≤ 00.00.01a2023-01-13
CVE-2022-41778 [HIGH] CWE-502 CVE-2022-41778: Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied d Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
nvd
CVE-2023-46690P3HIGHCVSS 8.8v1.0.72023-11-30
CVE-2023-46690 [HIGH] CWE-35 CVE-2023-46690: In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacke In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution.
nvd
CVE-2023-1143P3HIGHCVSS 8.8fixed in 1.0.52023-03-27
CVE-2023-1143 [HIGH] CVE-2023-1143: In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scr In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.
nvd
CVE-2023-1137P3HIGHCVSS 8.8fixed in 1.0.52023-03-27
CVE-2023-1137 [HIGH] CWE-522 CVE-2023-1137: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation.
nvd
CVE-2023-0444P3HIGHCVSS 8.8v00.00.02a2023-01-26
CVE-2023-0444 [HIGH] CVE-2023-0444: A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator.
nvd
Deltaww Infrasuite Device Master vulnerabilities | cvebase