Siemens Simatic Et 200Sp Open Controller Cpu 1515Sp Pc vulnerabilities
20 known vulnerabilities affecting siemens/simatic_et_200sp_open_controller_cpu_1515sp_pc.
Total CVEs
20
CISA KEV
0
Public exploits
0
Exploited in wild
0
Severity breakdown
CRITICAL7HIGH7MEDIUM6
Vulnerabilities
Page 1 of 1
CVE-2020-15782P2CRITICALCVSS 9.8vAll versions2021-05-28
CVE-2020-15782 [CRITICAL] CWE-119 CVE-2020-15782: A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMA
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.
nvd
CVE-2026-63350P3CRITICALCVSS 9.6fixed in *2026-10-13
CVE-2026-63350 [CRITICAL] CWE-95 CVE-2026-63350: Affected devices do not properly restrict executable content contained in imported trace files. T
Affected devices do not properly restrict executable content contained in imported trace files.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s br
nvd
CVE-2026-25787P3CRITICALCVSS 9.1fixed in *2026-05-12
CVE-2026-25787 [CRITICAL] CWE-79 CVE-2026-25787: Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "
Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page.
If a benign user with appropriate rights access
nvd
CVE-2026-63354P3CRITICALCVSS 9.6fixed in *2026-10-13
CVE-2026-63354 [CRITICAL] CWE-79 CVE-2026-63354: Affected devices do not properly validate and sanitize visual marker data contained in imported CSV
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow a
nvd
CVE-2026-63353P3CRITICALCVSS 9.6fixed in *2026-10-13
CVE-2026-63353 [CRITICAL] CWE-79 CVE-2026-63353: Affected devices do not properly sanitize comment fields contained in imported trace files before re
Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled
nvd
CVE-2026-25786P3CRITICALCVSS 9.1fixed in *2026-05-12
CVE-2026-25786 [CRITICAL] CWE-79 CVE-2026-25786: Affected devices do not properly validate and sanitize PLC/station name rendered on the "communicati
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface.
This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page.
If a benign user with appropriate rights accesses the "commu
nvd
CVE-2025-40943P3CRITICALCVSS 9.6fixed in *2026-03-10
CVE-2025-40943 [CRITICAL] CWE-95 CVE-2025-40943: Affected devices do not properly sanitize contents of trace files. This could allow an attacker t
Affected devices do not properly sanitize contents of trace files.
This could allow an attacker to inject code through social engineering an authorized user, who has the function right "Read diagnostics", to import a specially crafted trace file.
The malicious trace file is insufficiently sanitized and malicious code could be executed in the clients
nvd
CVE-2021-37204P3HIGHCVSS 7.5vAll versions2022-02-09
CVE-2021-37204 [HIGH] CWE-672 CVE-2021-37204: A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMA
A vulnerability has been identified in SIMATIC Drive Controller family (All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over
nvd
CVE-2019-10943P3HIGHCVSS 7.5vAll versions2019-08-13
CVE-2019-10943 [HIGH] CWE-353 CVE-2019-10943: A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 20
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions = V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions = V4.4.0), SIMATIC
nvd
CVE-2019-10936P3HIGHCVSS 7.5fixed in V2.02019-10-10
CVE-2019-10936 [HIGH] CWE-400 CVE-2019-10936: Affected devices improperly handle large amounts of specially crafted UDP packets. This could all
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
nvd
CVE-2022-38465P3HIGHCVSS 7.8vAll versions2022-10-11
CVE-2022-38465 [HIGH] CWE-522 CVE-2022-38465: A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMA
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0)
nvd
CVE-2019-19300P3HIGHCVSS 7.5fixed in V2.02020-04-14
CVE-2019-19300 [HIGH] CWE-400 CVE-2019-19300: A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, De
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET 20
nvd
CVE-2026-25789P3HIGHCVSS 7.1fixed in *2026-05-12
CVE-2026-25789 [HIGH] CWE-79 CVE-2026-25789: Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This c
Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote attacker to social engineer the user into selecting the modified firmware file to be uploaded. This would result in malitcious JavaScript execution in the context of the authenticated user's session without requiring the file to be up
nvd
CVE-2019-6568P3HIGHCVSS 7.5vAll versions < V2.1.62019-04-17
CVE-2019-6568 [HIGH] CWE-125 CVE-2019-6568: The webserver of the affected devices contains a vulnerability that may lead to a denial of service
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network
access to the affected systems. Successful exploitat
nvd
CVE-2026-63357P4MEDIUMCVSS 6.1fixed in *2026-10-13
CVE-2026-63357 [MEDIUM] CWE-79 CVE-2026-63357: Affected devices do not properly sanitize calculated signal data contained in imported calculated si
Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted file. Successful exploitation could allow attacker-
nvd
CVE-2019-10929P4MEDIUMCVSS 5.9vAll versions2019-08-13
CVE-2019-10929 [MEDIUM] CWE-327 CVE-2019-10929: A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Control
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versio
nvd
CVE-2026-63351P4MEDIUMCVSS 6.1fixed in *2026-10-13
CVE-2026-63351 [MEDIUM] CWE-79 CVE-2026-63351: Affected devices do not properly validate and sanitize visual properties of calculated signals conta
Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful expl
nvd
CVE-2026-63355P4MEDIUMCVSS 6.1fixed in *2026-10-13
CVE-2026-63355 [MEDIUM] CWE-79 CVE-2026-63355: Affected devices do not properly sanitize signal names contained in imported CSV trace files before
Affected devices do not properly sanitize signal names contained in imported CSV trace files before rendering them in selection menus on the Trace page.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Attacker-controlled JavaScript could
nvd
CVE-2026-63356P4MEDIUMCVSS 6.1fixed in *2026-10-13
CVE-2026-63356 [MEDIUM] CWE-79 CVE-2026-63356: Affected devices do not properly sanitize calculated signal names contained in imported CSV trace fi
Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before including them in error messages on the Trace page.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Attacker-controlled JavaSc
nvd
CVE-2026-63352P4MEDIUMCVSS 6.1fixed in *2026-10-13
CVE-2026-63352 [MEDIUM] CWE-79 CVE-2026-63352: Affected devices do not properly sanitize calculated signal data contained in imported CSV trace fil
Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page.
This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-co
nvd